Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Tools

  • Flush Cutters

  • 4mm Hex

  • 10mm Socket/Wrench

Step 1: Lower Bed and Power Off Machine

Using the front screen navigate to actions > move and press Z- to lower the bed to Z150.

You can then shut the machine off by going to config > system > shutdown > printer. Move the power switch at the back of the machine to the off position.

Step 2: Remove Bed Fastener

Using a 4mm hex and 10mm socket remove the three countersunk screws holding down the bed. Set this hardware in a safe place as we will be reusing them.

Image Added

Step 3: Unplug Connectors

Unplug the heater and temperature connectors. Take note of the release tabs shown below:

Image Added
Image Added

Image Added