Tools
Flush Cutters
4mm Hex
10mm Socket/Wrench
Step 1: Lower Bed and Power Off Machine
Using the front screen navigate to actions > move and press Z- to lower the bed to Z150.
You can then shut the machine off by going to config > system > shutdown > printer. Move the power switch at the back of the machine to the off position.
Step 2: Remove Bed Fastener
Using a 4mm hex and 10mm socket remove the three countersunk screws holding down the bed. Set this hardware in a safe place as we will be reusing them.
Step 3: Unplug Connectors
Unplug the heater and temperature connectors. Take note of the release tabs shown below: